-40%

1 CH Wireless Remote Control System with Delay Time Function 0-99 seconds

$ 22.17

Availability: 10 in stock
  • Country of Manufacture: China
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Item must be returned within: 30 Days
  • Type: Home Automation Module
  • All returns accepted: Returns Accepted
  • Condition: New
  • Brand: CaryMart
  • MPN: Does Not Apply

    Description

    0020011
    1 CH Wireless Remote Control System with Delay Time Function 0-99 seconds
    Model:  0020011
    Package  Include:
    1 x Receiver: S1UD-DC06 / S1UD-DC09 / S1UD-DC12 / S1UD-DC24 (1 Channel / Three  Control Modes)
    2 x Transmitter: C-2
    1 x User manual
    Feature:
    Wireless control, easy to install
    Setting delay time from 0 to 99 seconds.
    Control Lights, Motors, Fans, electrically operated  Doors/Locks/Windows/Blinds/Cars or Other Appliances with voltage AC110~240V or  DC0~28V.
    You can turn on/off the receiver with transmitter (remote control) from any  place within a reliable distance; the wireless RF signal can pass through walls,  floors and doors.
    With characteristics of reverse power protection.
    Use an 8-bit microcontroller with low-power and high-speed CMOS technology.
    Reliable control: The transmitter (Encoding) and the receiver (Decoding) use an  8-bit code.
    One/ several transmitters can control one/ several receivers simultaneously.
    If you use two or more receivers in the same place, you can set them with  different codes.
    Transmitting Frequency: 433MHz
    Receiver Parameters:
    Model No.: S1UD-DC06 / S1UD-DC09 / S1UD-DC12 / S1UD-DC24
    Channel: 1 CH
    Control Modes: Toggle, Momentary, Latched
    Delay time: 0~99 seconds
    Coding Type: Fixed code or Learning code
    Coding Setting: By learning
    Power Supply (Operating Voltage): DC6V (S1UD-DC06), DC12V±1V (S1UD-DC12),  DC9V±1V (S1UD-DC09), DC24V±1V (S1UD-DC24)
    Working Voltage Range of Relay: AC110~240V or DC0~28V
    Output: Relay output (Normally open and normally closed)
    Maximum Working Current of Relay: 7A
    PCB Size: 45mm x 30mm x 15mm
    Case Size: 50mm x 35mm x 23mm
    Receiver Sensitivity:-114dbm
    Static Current: ≤10mA
    Transmitter:
    Model No.: C-2
    Channel: 2 CH
    Remote Control Distance: 100m / 300ft (theoretically)
    Encode: Fixed code by soldering
    Unit size: 58mm x 39mm x 16mm
    Power Supply: 1 x 23A -12V battery (included, can be used for 12 months)
    Usage:
    Initial state: Terminals A, B = Normally Closed; Terminals B, C = Normally Open.
    Connect device to terminal “B & C”; connect power supply to terminal “+” and  “-”.
    Setting different control modes (We have set the receiver as Toggle control mode  before delivery. If you want to use other control modes, do as following  operation):
    Setting control mode Toggle: Connect Jumper-2 and Jumper-3.
    Control mode Toggle: Press -> On; Press again -> Off.
    Press button 1: Turn on the relay (connect B and C, disconnect A and B)
    Press button 1 again: Turn off the relay (disconnect B and C, connect A and B)
    If you set delay time, such as 30 seconds:
    Press button 1: Turn on the relay (connect B and C, disconnect A and B)
    After 30 seconds, Turn off the relay automatically (disconnect B and C, connect  A and B). Or press button 1 again within 30 seconds: Turn off the relay  immediately.
    Setting control mode Momentary: Disconnect Jumper.
    Control mode Momentary: Press and hold -> On; Release -> Off.
    Press and hold button 1: Turn on the relay (connect B and C, disconnect A and B)
    Release button 1: Turn off the relay (disconnect B and C, connect A and B)
    If you set delay time, such as 20 seconds:
    Press and hold button 1: Turn on the relay (connect B and C, disconnect A and B)
    After 20 seconds, Turn off the relay automatically (disconnect B and C, connect  A and B). And the relay couldn’t be turned off by pressing any button within 20  seconds.
    Setting control mode Latched: Connect Jumper-1 and Jumper-2.
    Control mode Latched: Press -> On, other relays Off; Press another button ->  Off.
    Press button 1: Turn on the relay (connect B and C, disconnect A and B)
    Press button 2: Turn off the relay (disconnect B and C, connect A and B)
    If you set delay time, such as 10 seconds:
    Press button 1: Turn on the relay (connect B and C, disconnect A and B)
    After 10 seconds, Turn off the relay automatically (disconnect B and C, connect  A and B). Or press button 2 within 10 seconds: Turn off the relay immediately.
    Delay  time setting function:
    Press the setting button, the LED off, that means enter into the delay time  setting mode.
    Then you can set delay time through pressing the learn button. Press the learn  button, LED will flash once, that means the delay time increase 1 seconds, if  you want to delay 30 seconds, you need to press the learn button with 30 times.
    You can set longest delay time to 99 seconds.
    Press the setting button again, the delay time what you have set will be  preserved forever even if you turn off power. After the delay time is preserved  by the system, LED will flash 3 times, the system will quit the delay time  setting mode.
    For example, when you use this receiver to control one lamp, and you already set  30 seconds delay time, you can press button 1 to turn on the lamp, and the lamp  will turn off automatically after 30 seconds. If you don’t need the delay  function, you should clear the delay time.
    Clear  delay time:
    If you don’t want to set the delay time, you can operate as following:
    Press the setting button and enter into the delay time setting mode, the delay  time what you have set will be cleared automatically.
    Press the setting button again, LED will flash 3 times, the system will quit the  delay time setting mode.